corporate governance
Policies and Management Systems
Continuous improvement of our management systems
Our business units apply management systems specifically adapted to their activities and
business needs. These systems are designed to focus our company’s EH&S objectives, improve
worker safety, reduce adverse impacts on health and the environment, and measure our progress.
A goal of these systems is to increase the consistency of our EH&S activities and to ensure our
activities are closely tied to our business and CSR objectives. In 2005, we continued to strengthen
these systems:
- DuPont Safety Resources completed a comprehensive review of Liquids Pipelines’ Health
and Safety Management Systems to determine what we are doing well and where we need
to make improvements. DuPont’s four key recommendations focused on “felt” leadership,
employee involvement, enhancement of policies and procedures, and management of
contractors. We are now working on improving our health and safety programs in line with
the recommendations. A similar review of Liquids Pipelines’ Environmental Management
Systems has been commissioned for 2006.
- In 2005, Enbridge Gas Distribution continued to integrate its EH&S programs and
policies into the company’s Distribution Management System (DMS). The DMS is a customized
management system based on the framework adopted by the corporation to comply with the
Sarbanes-Oxley Act and the ISO framework. We process-mapped the majority of the company’s
EH&S programs, identified process stakeholders, and identified process gaps and scheduled
them for closure. For example, the company’s EHS Training Management process, Contractor
Safety Management process, and Chemical Management process each underwent a thorough
review by all stakeholders involved, followed by a concerted effort at implementing identified
opportunities for improvement in these processes. Overall, the introduction of the DMS to
Enbridge Gas Distribution ensures that employees know and understand the systems and
controls that are in place for employee safety and environmental protection, and improves
the ease and opportunity of conducting checks and audits on the system’s effectiveness and
efficiency going forward.
- We continued to strengthen EH&S compliance in our United States Natural Gas Business
through the use of our Ops Environmental compliance database system, an online set of EH&S
tracking and notification tools that help staff in monitoring compliance with federal, state and
internal requirements. We have successfully put this system into effect in all areas of the United
States Natural Gas Business, including the Gulf of Mexico offshore assets we acquired at the
beginning of 2005.
We use reviews and audits to assess each business segment’s compliance with government
regulations and our internal policies and management systems, and to provide guidance for
making improvements.
Internal EH&S reviews
We conduct internal EH&S reviews at all facilities we operate. To carry out a review, a team
of EH&S professionals inspects the site, conducts interviews, and checks documentation. After
the review is completed, the team provides local management with a formal written review report
summarizing the findings. Management then develops an action plan to correct deficiencies.
The review team follows up on documented issues to ensure they are fully addressed.
- Environmental reviews were conducted on the Enbridge Pipelines (NW) Inc. system, Enbridge
Energy Partners L.P/ Cushing Region and the Hardisty Caverns Limited Partnership facility.
These reviews are an integral component of the Enbridge Environmental Management System
and consist of a formalized program of inspections and reviews to monitor compliance with
regulatory requirements, Enbridge policies and procedures, and industry best practices.
- In mid-2005, our United States Natural Gas Business implemented a new corporate EH&S
audit program designed to ensure compliance and consistency across our various assets. We
completed 11 audits in the second half of the year. Our field EH&S personnel also performed
81 additional internal audits.
- Enbridge Gas Distribution reviewed one-third (13) of the company’s gate stations in 2005
for compliance with environment and health and safety regulations. The company also completed
an EH&S compliance review at its meter shop facility, and is on track for reviewing three of its
operations stations in 2006. The compliance review process is proving valuable in identifying
issues, tracking closure of issues, communicating expectations to relevant internal groups, and
maintaining strong EH&S compliance across company facilities.
External audits and inspections
Local and federal regulatory agencies carry out environmental and safety audits and inspections
of our operations. Here are some examples:
- The Oklahoma Department of Environmental Quality completed a comprehensive hazardous
waste inspection at Liquids Pipelines’ Cushing tank farm. No deficiencies were identified. In
addition, our Vector Pipeline compressor stations in Indiana and Michigan received air compliance
inspections by the respective state environmental agencies, also with no notable deficiencies.
- Regulatory agencies conducted 96 external audits at our United States Natural Gas Business
facilities in 2005. These audits resulted in two violation notifications. Both of these violations were
the result of exceeding emission limits at two separate gas plants. One violation was minor
and did not result in a fine, and the other was more significant and is described in more detail in
the section below.
- The United States Natural Gas Business also received three additional violation notifications
in 2005 for reporting, record keeping and operating variances that were discovered by agencies
conducting files reviews.
We manage compliance with laws and regulations through system controls and regular reviews
and inspections. We consider any regulatory notification or penalty to be important and continue to
work toward our goal of continuous compliance. In the event that our performance falls short of this
goal, we carry out rigorous reviews and institute corrective processes.
In 2005, we received 10 regulatory notifications from government agencies for environmental
or safety issues:
- Our United States Natural Gas Business received five notices of violation/enforcement for
air permit and non-compliance issues. The most significant was a US$22,500 fine issued to
our Plum Creek, Texas, natural gas treating plant. A Notice of Enforcement (NOE) was issued
for failure to meet sulphur dioxide emission limits of 42.01 pounds/hour. This NOE is in
reference to what Enbridge described as “dramatic variations in the inlet gas’s composition”,
which resulted in the plant experiencing SO2 emissions greater than the permitted limits.
We have since changed operating parameters at the plant to prevent a reoccurrence in the future.
- Liquids Pipelines received four notices – three from the United States Department of
Transportation’s Pipeline and Hazardous Materials Safety Administration and one from the
Illinois Environmental Protection Agency. None were significant violations or bore any monetary
fines, and all four were addressed and resolved.
- Enbridge Gas Distribution received one minor administrative order from the Ontario
Ministry of Labour, related to construction work at our main Toronto office. The order cited
that the company was to post temporary emergency evacuation procedures consistent with the
construction flow and work being accomplished during renovation and that the notice of project
identify Enbridge Gas Distribution as the primary constructor. We complied immediately with the
order, and we reviewed the issues to prevent future recurrences.
Regulatory notifications and fines
| |
2002 |
2003 |
2004 |
2005 |
| Regulatory notifications* |
7 |
21 |
28 |
10 |
| Regulatory fines incurred (US$) |
16,900 |
54,000 |
207,278 |
101,114** |
* Regulatory notifications are formal written notices by regulators that Enbridge may not be adhering to the law,
regulation or permit requirements. Examples include formal warnings, enforcement actions, summons and charges,
notices of violation and stop and control orders.
** In 2005, Gas Pipelines received a fine of US$69,300 for exceeding operating permit levels for carbon monoxide at the
Highland, Michigan compressor station on the Vector pipeline during 2004. We took corrective action, modifying equipment
and operating practices, in consultation with the United States Environmental Protection Agency and state regulators.
Top of pageSettlement agreement reached in Garland late payment penalty proceedings
Enbridge Gas Distribution has entered into a settlement agreement in a proposed class proceeding
related to late payment penalties charged in the past by Enbridge Gas Distribution. Under the proposed
settlement, Enbridge Gas Distribution will make payments of $21.2 million, including a one-time
payment of $9 million prior to the end of January 2007 to the Winter Warmth Fund which we have
been supporting since 2004; $10.2 million to class counsel on account of the plaintiff’s legal fees
and expenses; and approximately $2 million to the Class Proceedings Fund operated by the Law
Foundation of Ontario. This settlement does not constitute any admission of liability on the part
of Enbridge Gas Distribution. The settlement agreement is subject to the approval of the Ontario
Superior Court of Justice.
Late payment penalty revenues are included in Enbridge Gas Distribution’s estimate of revenues
for the year and therefore accrue to the benefit of all customers, reducing the cost of providing
distribution services. The Ontario Energy Board (OEB) approves these estimates and resulting
rates each year. Enbridge Gas Distribution intends to apply to the OEB for recovery of the proposed
payments resulting from the settlement of this action.
|